Below is a Production of Foam Cell Concrete Guide using Batimix Cell 645 Admixture in a Batching Plant
1. Introduction
Foam cell concrete, also known as cellular lightweight concrete (CLC), is a cement-based material that contains a homogeneous distribution of stable air cells throughout its mass. It combines reduced density with adequate compressive strength, making it ideal for applications such as roof insulation, void filling, and non-structural block production.
When produced using an Batimix Cell 645 liquid foaming admixture, foam cell concrete can be batched efficiently in a standard concrete plant. The admixture introduces and stabilizes uniform air cells in the mix through its surfactant action, resulting in a consistent, lightweight, and thermally efficient concrete.
2. Materials
3. Water Quality Requirements
The performance and stability of foam cell concrete are highly dependent on the quality of the mixing water. Since the Batimix Cell 645 foaming admixture relies on surface activity and chemical balance, water purity is critical for stable foam formation and consistent results.
a. Potable or Purified Water Requirement
Clean Reverse Osmosis water is recommended for all foam concrete production that is free from harmful impurities like oils, acids, organic matter, sulfates, and chlorides that can disrupt the foaming action or cement hydration.
b. Reasons for Using Potable or Clean Water
c. Reverse Osmosis (RO) Water**
RO water is highly recommended, as it provides exceptional consistency and purity. It removes nearly all dissolved salts, ions, and organics, ensuring chemical compatibility with Batimix Cell 645. Clean water is used as it has the following properties:
If switching between RO and other water sources, maintain stable water quality to avoid minor variations in foam behavior.
d. Alternative Water Sources
Non-potable water (e.g., from wells or recycled wash water) may be used only after laboratory testing confirms that it does not negatively affect foam generation, setting, or strength.
e. Standards
Water quality should comply with ASTM C1602 or EN 1008 standards.
If the water is fit to drink, it is fit for making foam concrete.
4. Mechanism of Action
Batimix Cell 645 acts as a surface-active agent, reducing the surface tension of the mixing water and enabling air incorporation during mixing or pre-foaming. The fatty acid salt structure of Potassium Oleate forms a thin, elastic film around air bubbles, stabilizing them against coalescence and collapse. These air cells remain evenly distributed during mixing and hardening, producing a homogenous cellular matrix.
5. Production in a Concrete Batching Plant
5.1 Equipment Requirements
Batching Unit: Standard plant with calibrated dosing systems for cement, aggregates, and admixtures.
Mixer: Planetary or twin-shaft mixer capable of vigorous agitation to ensure uniform air dispersion.
Foam Admixture Dispensing System:
Foam Generator (for pre-foamed process):
5.2 Mixing Methods
A. Direct Foaming in the Mixer
Continue mixing for 2–3 minutes until the mixture exhibits uniform cellular texture and creamy consistency.
B. Pre-Foamed Method
Do not overmix; excessive agitation can destroy the air structure.
5.3 Dosage Rates
Recommended dosage of Batimix Cell 645 depends on the target density and required foam stability.
| Target Density (kg/m³) | Dosage (% of Cement Weight) | Foam Density (g/L) | Water/Cement Ratio |
|---|---|---|---|
| 1800 – 1600 | 0.4 – 0.6% | 90–100 | 0.40 – 0.45 |
| 1600 – 1400 | 0.6 – 0.8% | 80–90 | 0.45 – 0.50 |
| 1400 – 1200 | 0.8 – 1.0% | 70–80 | 0.50 – 0.55 |
| 1200 – 800 | 1.0 – 1.5% | 60–70 | 0.55 – 0.60 |
Note: Optimize dosage through laboratory trials considering cement fineness, sand gradation, and mixing energy.
6. Dispensing and Quality Control
7. Placement and Curing
8. Features and Advantages
| Property | Description |
|---|---|
| Lightweight | Density between 800–1800 kg/m³ reduces dead load. |
| Stable Air Structure | Potassium Oleate forms durable air films resistant to collapse. |
| Thermal/Acoustic Insulation | Excellent energy and sound performance. |
| Pumpable & Flowable | Easily placed without vibration. |
| Eco-Friendly | Reduced cement use and suitable for supplementary materials. |
| Fire Resistant | Non-combustible, ideal for insulation layers. |
| Economical | Requires no special plant modifications. |
9 Testing and Quality Control
10. Applications
11. Conclusion
Using an Batimix Cell 645 liquid foaming admixture enables efficient and consistent foam cell concrete production in standard batching plants. Proper water quality—especially when using potable or reverse osmosis water—is crucial for foam stability and performance. Controlled dosing, optimized mixing, and reliable curing ensure a uniform, durable, and lightweight concrete suited to modern sustainable construction needs.
Statement of Responsibility: The information and application advice contained in this document are based on the present state of scientific and practical knowledge of Holderchem SAL. It is provided with no warranty, implied or otherwise, as to its completeness or accuracy. Since methods and conditions of application and use are beyond the control of Holderchem, HOLDERCHEM MAKES NO WARRANTIES, IMPLIED OR OTHERWISE, AS TO THE MERCHANTABILITY OR FITNESS FOR ORDINARY OR PARTICULAR PURPOSES OF ITS PRODUCTS AND EXCLUDES THE SAME. Holderchem warrants that its products shall be of sound materials and workmanship. As products are applied, handled and stored in manners and site conditions over which Holderchem has no control, Holderchem's liability in respect of any material which can be proven defective shall be limited to the replacement of such defective material or reimbursement of its cost at Holderchem's option. Holderchem shall not be liable for any consequential or incidental damage or loss arising out of the use of its products. Important Note: Holderchem shall have the right to modify product specification sheets at any time without previous notice. Buyers should always refer to the most recent data sheets, copies of which can be supplied upon request. The sale of products mentioned in this literature shall be subject to Holderchem's General Conditions of Sale Delivery and Payment.